  • Standard Version: 50 mm, 63 mm & 80 mm
  • Accuracy: 1.6% of F. S. (for NS 63 mm & NS 80 mm) / 2.5% of F. S. (for NS 50 mm)

AL

  • Accuracy: 1.0% of F. S.
  • Standard Version: 100 mm, 125 mm, 150 mm, 200 mm & 250 mm

BE

  • Standard Version: 63 mm, 100 mm & 150 mm
  • Accuracy: 1.0% of F. S. for NS 100 mm & 150 mm / 1.6% of F. S. for NS 63 mm

BV

  • Standard Version: 100 mm & 150 mm
  • Accuracy: 1.6% of F. S.
endif;

BI

  • Standard Version: 100 mm
  • Accuracy: 1.0% of F. S.

BI

  • Standard Version: 100 mm & 150 mm
  • Accuracy: 1.0% of F. S.
endif;

AQ

  • Standard Version: 100 mm & 150 mm
  • Accuracy: 1.6% of F. S. (for ascending order)

BQ

  • Standard Version: 150 mm
  • Accuracy: 1.6% of F. S. (for ranges up to 1 bar)
  • 1.0% of F. S. for ranges 1 bar to 6 bar

BF

  • Standard Version: 63 mm, 100 mm & 150 mm
  • Accuracy: 2% of F. S. (for ascending order)
endif;

AT

  • Standard Version: 50 mm, 63 mm, 80 mm & 100 mm
  • Accuracy: 1.6% of F. S. (for NS 63 mm, 80 mm & 100 mm) / 2.5% of F. S. (for NS 50 mm)
endif;

AJ

  • Standard Version: 150 mm
  • Accuracy: 0.25% of F. S. (at +20 C)

AR

  • Standard Version: 150 mm, 200 mm & 250 mm
  • Accuracy: 0.25% of F. S. (at +20 C)
endif;

AH

  • Standard Version: 4″
  • Accuracy: 0.5% of F. S. (as per ASME B40.100)

AI

  • Standard Version: 100 mm & 150 mm
  • Accuracy: 1.0% of F. S.
endif;

AF

  • Standard Version: 63 mm, 100 mm, 125 mm & 150 mm/li>
  • Accuracy: 1.6% of F. S.
endif;

AY

  • Standard Version: 50 mm & 63 mm
  • Accuracy: 1.6% of F. S.
endif;

CombiPress PFMN

  • Pressure transmitter / switch
  • Flush diaphragm
  • FlexHousing
  • DFON display
  • Programmable and auto-zero adjustable

CombiPress PFMH

  • Pressure transmitter / switch
  • Hygienic
  • Flush diaphragm, 3-A and EHEDG certified
  • CombiViewDFON display
  • CIP / SIP-able
  • Programmable and 0-adjustment

(Y)TED

  • Pressure switch
  • Two threshold outputs (PNP transistors or galvanic isolation)
  • Intrinsically safe version
  • Robust stainless steel housing for severe industrial environments

(Y)TED hygienic

  • Hygienic pressure switch
  • Two threshold outputs (PNP transistors or galvanic isolation)
  • Flush membrane with hygienic approval (3-A)
  • Robust stainless steel housing for severe industrial environments

CPX

  • Two threshold outputs (PNP transistors)
  • Compact and light-weight design
  • Measuring range: -1…0 to 0600 bar
endif;

ZDT

  • Type: Rigid stem / capillary
  • Temperature Range : 10 … 400 C
  • Repeatability: 1% F.S.
  • Switch Rating: 15 A, 250 VAC, 0.2 A, 220 VDC

RT2N

  • Compact temperature switch
  • Good vibration resistance
  • Measuring ranges: -40…+350C
  • Stem 9.0 mm (rigid or with capillary)

RT2Y

  • Compact temperature switch
  • Approval: ATEX EEx ia
  • Godd vibration resistance
  • Measuring ranges: -40…+350C

RT2E

  • Compact temperature switch
  • Approval: ATEX EEx d
  • Godd vibration resistance
  • Measuring ranges: -40…+350C
  • Stem 9.0 mm (rigid or with capillary)

RTN

  • Standard temperature switch
  • Adjustable setpoint(s) and deadband
  • Godd vibration resistance
  • Measuring ranges: -40…+350C
  • Stem 14mm (rigid or with capillary)

RTNY

  • Standard temperature switch
  • Approval: ATEX EEx ia
  • Adjustable setpoint(s) and deadband
  • Measuring ranges: -40…+350C
  • Stem 14mm (rigid or with capillary)

RTNE

  • Standard temperature switch
  • Approval: ATEX EEx d
  • Adjustable setpoint(s) and deadband
  • Measuring ranges: -40…+350C
  • Stem 14mm (rigid or with capillary)

ETTN / YTTN

  • On site configuration
  • Suitable for hazardous areas
  • Ideal for safety circuits
  • Robust design for rugged industrial enviroment
endif;